Weil-McLain Boiler: Massachusetts venting requirements for sidewall horizontal vent

Updated · by Aurora Star Tech Inc.

Massachusetts venting requirements for sidewall horizontal vent on a Weil-McLain boiler: Applies to sidewall horizontally vented gas equipment in dwellings or residential buildings where the vent termination is under 7 ft above grade. Carbon monoxide detectors and a warning sign are required, and the local gas inspector checks them before approving the install. Exempt equipment includes units in a separate building or structure and equipment listed in NFPA 54 Chapter 10.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Sidewall horizontal vent installations in Massachusetts

How to fix massachusetts venting requirements for sidewall horizontal vent: step by step

  1. Confirm the installation is a sidewall horizontal vent with the termination under 7 ft above grade.
  2. Confirm a hard-wired CO detector with alarm and battery backup is on the floor level where the boiler is installed.
  3. Confirm a battery or hard-wired CO detector with alarm is on each additional level served.
  4. If the requirements cannot be met at completion, a battery-operated CO detector with alarm must be installed in the interim, and the owner has 30 days to comply.
  5. Confirm CO detectors are listed to NFPA 720 and ANSI/UL 2034 and IAS certified.
  6. Confirm a metal or plastic sign at least 8 ft above grade, in line with the vent terminal, reads GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS. with letters at least 1/2 inch high.
  7. Leave the installation instructions, venting instructions and parts lists with the appliance.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SVF Series 1 Boiler Manual, p. 24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.