Weil-McLain Boiler: Check automatic air vents
Check automatic air vents on a Weil-McLain boiler: Only applies to systems with diaphragm-type expansion tanks. Water from the vent can be very hot.
Applies to: Evergreen Series 2 110/155/220/299/300/399
How to fix check automatic air vents: step by step
- Remove the cap from the automatic air vent.
- Press the vent valve B briefly with a screwdriver tip to check it moves freely and does not leak.
- Replace cap A and turn it fully on.
- Loosen cap A one turn so the vent can operate.
- Replace the vent if it does not work correctly.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain Condensing Gas Boiler User's Information Manual, p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.