Weil-McLain Boiler: Alarm and additional heat demand dry contacts
Alarm and additional heat demand dry contacts on a Weil-McLain boiler: The alarm contact on P16 terminals 4 and 5 closes when the boiler enters lockout, for remote alarm notification. The additional heat demand contact on P16 terminals 6 and 7 starts another heat source. Both are low voltage only.
Applies to: Ultra U-Control dry contacts
How to fix alarm and additional heat demand dry contacts: step by step
- Connect the remote alarm to P16 terminals 4 and 5 if notification is needed.
- Connect the next heat source to P16 terminals 6 and 7 if using additional heat demand.
If the unit shows an error code, look it up: Weil-McLain Boiler codes
Source: Weil-McLain Ultra Series 4 boiler manual, p. 98. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.