Weil-McLain error code NO DISPLAY - NO 24V on a boiler means: No display, no 24V control power. It is also called Weil-McLain diagnostic code NO DISPLAY - NO 24V.

Medium severityBoilerSVF Series 1

Homeowner? What Weil-McLain code NO DISPLAY - NO 24V means for you

Check, then call Your boiler is reporting: No display, no 24V control power. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code NO DISPLAY - NO 24V mean?

Display stays blank and the boiler does not answer a call for heat. The control is not getting 24V power.

Applies to: SVF 1500-3000 Series 1 boiler

Common causes of Weil-McLain code NO DISPLAY - NO 24V

  • Short circuit or wrong wiring to the control
  • Blown 3 A low-voltage fuse on the control
  • Transformer not feeding 24VAC to the control
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
LOW WTR CUTOFF OPENLow water cutoff contacts open
LWCOLow water cutoff active / LWCO test
LWCO GREENLow water cutoff indicator green
LWCO REDLow water cutoff indicator red
MANUAL LIMITManual-reset limit circuit open (includes rollout switch)
NO DISPLAY - BOILER RUNNINGDisplay blank while boiler is operating
NO DISPLAY - NO 120VNo display and no boiler components running, no 120V power
RETURN > SUPPLYReturn temperature above supply
Software IncompatibleMain control and display software mismatch
SPILL SWITCHSpill switch open (flue gas spilling at the draft hood)
STANDBYStandby display
SUPPLY 58F > RETURNSupply temperature far above return

All Weil-McLain Boiler error codes →

Weil-McLain code NO DISPLAY - NO 24V: homeowner questions

What does Weil-McLain code NO DISPLAY - NO 24V mean?

No display, no 24V control power. Display stays blank and the boiler does not answer a call for heat. The control is not getting 24V power.

Is it safe to keep using my boiler with code NO DISPLAY - NO 24V?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Weil-McLain code NO DISPLAY - NO 24V myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code NO DISPLAY - NO 24V comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code NO DISPLAY - NO 24V near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Weil-McLain SVF Series 1 boiler manual, p. 103. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.