Weil-McLain Error Code SPILL SWITCH: Spill switch open (flue gas spilling at the draft hood) (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code SPILL SWITCH on a boiler means: Spill switch open (flue gas spilling at the draft hood). It is also called Weil-McLain diagnostic code SPILL SWITCH.

Critical severityBoilerWeil-McLain CGa Series 4

Homeowner? What Weil-McLain code SPILL SWITCH means for you

Stop and call Your boiler is reporting: Spill switch open (flue gas spilling at the draft hood). This code is a safety shutdown. Turn the boiler off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code SPILL SWITCH mean?

The spill switch on the draft hood opened, usually because the vent is blocked or wind is pushing flue gas back. The switch has its own manual reset button.

Applies to: CGa-25 to CGa-8, natural gas (config #15) and propane (config #5)

Common causes of Weil-McLain code SPILL SWITCH

  • Blocked or restricted vent or chimney
  • Down draft from wind
  • Failed spill switch
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
MANUAL LIMITManual-reset limit circuit open (includes rollout switch)
NO DISPLAY - BOILER RUNNINGDisplay blank while boiler is operating
NO DISPLAY - NO 24VNo display, no 24V control power
NO DISPLAY - NO 120VNo display and no boiler components running, no 120V power
RETURN > SUPPLYReturn temperature above supply
Software IncompatibleMain control and display software mismatch
STANDBYStandby display
SUPPLY 58F > RETURNSupply temperature far above return
SUPPLY 58° F > RETURNSupply exceeds return by 58°F
Supply 60F > ReturnSupply more than 60F above return (soft lockout)
SUPPLY WATER TEMPERATURE TOO HIGHSupply temperature above 200°F while burner runs
System Return > SupplySystem return hotter than system supply

All Weil-McLain Boiler error codes →

Weil-McLain code SPILL SWITCH: homeowner questions

What does Weil-McLain code SPILL SWITCH mean?

Spill switch open (flue gas spilling at the draft hood). The spill switch on the draft hood opened, usually because the vent is blocked or wind is pushing flue gas back. The switch has its own manual reset button.

Is it safe to keep using my boiler with code SPILL SWITCH?

No. Code SPILL SWITCH is a safety shutdown, so keep the boiler off until a licensed technician has checked it.

Can I reset Weil-McLain code SPILL SWITCH myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Weil-McLain code SPILL SWITCH near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Weil-McLain CGa Series 4 Boiler Manual 550-100-223/0425, Table 11 Control fault information and troubleshooting, p.67 (parts p.70). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.