Weil-McLain Error Code DHW: Domestic hot water call active (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code DHW on a boiler means: Domestic hot water call active. It is also called Weil-McLain diagnostic code DHW.

Low severityBoilerEG · PEG · Series 7

Homeowner? What Weil-McLain code DHW means for you

Usually minor Your boiler is reporting: Domestic hot water call active. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code DHW mean?

Shown on the default display during a domestic hot water call. The display uses a purple backlight.

Applies to: Unity-CI control, EG / PEG Series 7 boilers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
BOILER OUT SHORTBoiler outlet sensor shorted
BURNER ONBurner on status
CHCentral heat call active
CH VOLTAGE HIGHToo much voltage on the CH / Thermostat 1 input
CONFIG MISMATCHStored configuration does not match the harness
CONFIGURATIONControl board not configured
DHW VOLTAGE HIGHToo much voltage on the DHW / Thermostat 2 input
DISPLAY COMMDisplay communication lost
EXP BOARD COM FAULTExpansion board to U-Control communication fault
FALSE FLAMEFlame sensed when the gas valve is off
FAULT L1 POLARITYLine 1 polarity reversed
FAULT MANUAL LIMITManual limit fault

All Weil-McLain Boiler error codes →

Weil-McLain code DHW: homeowner questions

What does Weil-McLain code DHW mean?

Domestic hot water call active. Shown on the default display during a domestic hot water call. The display uses a purple backlight.

Is it safe to keep using my boiler with code DHW?

Usually yes. Code DHW is normally minor, but if it keeps coming back have it checked.

Can I reset Weil-McLain code DHW myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code DHW comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code DHW near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: EG / PEG Series 7 boiler manual, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977