Weil-McLain Error Code FAULT L1 POLARITY: Line 1 polarity reversed (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code FAULT L1 POLARITY on a boiler means: Line 1 polarity reversed. It is also called Weil-McLain diagnostic code FAULT L1 POLARITY.

High severityBoilerEG · PEG · Series 7

Homeowner? What Weil-McLain code FAULT L1 POLARITY means for you

Call a technician Your boiler is reporting: Line 1 polarity reversed. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code FAULT L1 POLARITY mean?

The control shows this when the incoming 120 VAC power has reversed polarity. The boiler will not cycle while it is displayed.

Applies to: Unity-CI control, EG / PEG Series 7 boilers

Common causes of Weil-McLain code FAULT L1 POLARITY

  • Incoming 120 VAC hot and neutral are reversed
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
CONFIGURATIONControl board not configured
DHWDomestic hot water call active
DHW VOLTAGE HIGHToo much voltage on the DHW / Thermostat 2 input
DISPLAY COMMDisplay communication lost
EXP BOARD COM FAULTExpansion board to U-Control communication fault
FALSE FLAMEFlame sensed when the gas valve is off
FAULT MANUAL LIMITManual limit fault
FLAME FAULTFlame detected when no flame should exist
FLAME LOSTFlame lost while running
FLUE TEMP TOO HIGHFlue gas temperature too high
GAS PRESSURE SW FAULTGas pressure switch open
GAS VALVE FAULTGas valve output circuit fault

All Weil-McLain Boiler error codes →

Weil-McLain code FAULT L1 POLARITY: homeowner questions

What does Weil-McLain code FAULT L1 POLARITY mean?

Line 1 polarity reversed. The control shows this when the incoming 120 VAC power has reversed polarity. The boiler will not cycle while it is displayed.

Is it safe to keep using my boiler with code FAULT L1 POLARITY?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code FAULT L1 POLARITY myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code FAULT L1 POLARITY comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code FAULT L1 POLARITY near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: EG / PEG Series 7 boiler manual, p. 35. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.