Weil-McLain error code EXP BOARD COM FAULT on a boiler means: Expansion board to U-Control communication fault. It is also called Weil-McLain diagnostic code EXP BOARD COM FAULT.

Medium severityBoilerUltra Series 4

Homeowner? What Weil-McLain code EXP BOARD COM FAULT means for you

Check, then call Your boiler is reporting: Expansion board to U-Control communication fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code EXP BOARD COM FAULT mean?

Communication between the expansion control board and the U-Control board has failed. Residential Ultra boilers do not use an expansion control board. Requires manual reset.

Applies to: Ultra Series 4 boilers

Common causes of Weil-McLain code EXP BOARD COM FAULT

  • Boiler size selected in the U-Control does not match the rating label
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
CH VOLTAGE HIGHToo much voltage on the CH / Thermostat 1 input
CONFIG MISMATCHStored configuration does not match the harness
CONFIGURATIONControl board not configured
DHWDomestic hot water call active
DHW VOLTAGE HIGHToo much voltage on the DHW / Thermostat 2 input
DISPLAY COMMDisplay communication lost
FALSE FLAMEFlame sensed when the gas valve is off
FAULT L1 POLARITYLine 1 polarity reversed
FAULT MANUAL LIMITManual limit fault
FLAME FAULTFlame detected when no flame should exist
FLAME LOSTFlame lost while running
FLUE TEMP TOO HIGHFlue gas temperature too high

All Weil-McLain Boiler error codes →

Weil-McLain code EXP BOARD COM FAULT: homeowner questions

What does Weil-McLain code EXP BOARD COM FAULT mean?

Expansion board to U-Control communication fault. Communication between the expansion control board and the U-Control board has failed. Residential Ultra boilers do not use an expansion control board. Requires manual reset.

Is it safe to keep using my boiler with code EXP BOARD COM FAULT?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Weil-McLain code EXP BOARD COM FAULT myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code EXP BOARD COM FAULT comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code EXP BOARD COM FAULT near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 boiler manual, p. 123. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977