Weil-McLain Error Code BURNER ON: Burner on status (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code BURNER ON on a boiler means: Burner on status. It is also called Weil-McLain diagnostic code BURNER ON.

Low severityBoilerEG · PEG · Series 7

Homeowner? What Weil-McLain code BURNER ON means for you

Usually minor Your boiler is reporting: Burner on status. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code BURNER ON mean?

Shown on the default display while the burner is firing.

Applies to: Unity-CI control, EG / PEG Series 7 boilers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
AIR PRESSURE SW FAULTAir pressure switch input open
AUTO LIMITAuto-reset limit circuit open
BLOWER FAULTBlower speed fault
BOILER OUT OPENBoiler outlet sensor open circuit
BOILER OUT SHORTBoiler outlet sensor shorted
CHCentral heat call active
CH VOLTAGE HIGHToo much voltage on the CH / Thermostat 1 input
CONFIG MISMATCHStored configuration does not match the harness
CONFIGURATIONControl board not configured
DHWDomestic hot water call active
DHW VOLTAGE HIGHToo much voltage on the DHW / Thermostat 2 input
DISPLAY COMMDisplay communication lost

All Weil-McLain Boiler error codes →

Weil-McLain code BURNER ON: homeowner questions

What does Weil-McLain code BURNER ON mean?

Burner on status. Shown on the default display while the burner is firing.

Is it safe to keep using my boiler with code BURNER ON?

Usually yes. Code BURNER ON is normally minor, but if it keeps coming back have it checked.

Can I reset Weil-McLain code BURNER ON myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code BURNER ON comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code BURNER ON near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: EG / PEG Series 7 boiler manual, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.