Weil-McLain error code BLOWER FAULT on a boiler means: Blower speed fault. It is also called Weil-McLain diagnostic code BLOWER FAULT.

High severityBoilerUltra Series 4

Homeowner? What Weil-McLain code BLOWER FAULT means for you

Call a technician Your boiler is reporting: Blower speed fault. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code BLOWER FAULT mean?

Blower cannot reach required speed or does not reach 0 RPM when off. Resets automatically after 1 hour or from manual reset on the screen.

Applies to: Ultra Series 4 boilers

Common causes of Weil-McLain code BLOWER FAULT

  • Loose or damaged blower harness or connections
  • Blower not stopping (reads non-zero RPM in standby)
  • No 120 V at blower motor or U-Control

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
AIR PRESSURE SW FAULTAir pressure switch input open
AUTO LIMITAuto-reset limit circuit open
BOILER OUT OPENBoiler outlet sensor open circuit
BOILER OUT SHORTBoiler outlet sensor shorted
BURNER ONBurner on status
CHCentral heat call active
CH VOLTAGE HIGHToo much voltage on the CH / Thermostat 1 input
CONFIG MISMATCHStored configuration does not match the harness
CONFIGURATIONControl board not configured
DHWDomestic hot water call active
DHW VOLTAGE HIGHToo much voltage on the DHW / Thermostat 2 input
DISPLAY COMMDisplay communication lost

All Weil-McLain Boiler error codes →

Weil-McLain code BLOWER FAULT: homeowner questions

What does Weil-McLain code BLOWER FAULT mean?

Blower speed fault. Blower cannot reach required speed or does not reach 0 RPM when off. Resets automatically after 1 hour or from manual reset on the screen.

Is it safe to keep using my boiler with code BLOWER FAULT?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code BLOWER FAULT myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code BLOWER FAULT comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code BLOWER FAULT near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 boiler manual, p. 122. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977