Weil-McLain Error Code NO DISPLAY – BOILER RUNNING: Display blank while boiler is operating (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code NO DISPLAY - BOILER RUNNING on a boiler means: Display blank while boiler is operating. It is also called Weil-McLain diagnostic code NO DISPLAY - BOILER RUNNING.

Low severityBoilerSVF Series 1

Homeowner? What Weil-McLain code NO DISPLAY - BOILER RUNNING means for you

Usually minor Your boiler is reporting: Display blank while boiler is operating. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code NO DISPLAY - BOILER RUNNING mean?

Display shows nothing but the boiler still runs. Communication from the control to the display is lost.

Applies to: SVF 1500-3000 Series 1 boiler

Common causes of Weil-McLain code NO DISPLAY - BOILER RUNNING

  • Loose connection at the display plug or control board
  • Faulty wire harness from display to control
  • Failed display module

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
LIMIT OPENExternal limit open
LOW WTR CUTOFF OPENLow water cutoff contacts open
LWCOLow water cutoff active / LWCO test
LWCO GREENLow water cutoff indicator green
LWCO REDLow water cutoff indicator red
MANUAL LIMITManual-reset limit circuit open (includes rollout switch)
NO DISPLAY - NO 24VNo display, no 24V control power
NO DISPLAY - NO 120VNo display and no boiler components running, no 120V power
RETURN > SUPPLYReturn temperature above supply
Software IncompatibleMain control and display software mismatch
SPILL SWITCHSpill switch open (flue gas spilling at the draft hood)
STANDBYStandby display

All Weil-McLain Boiler error codes →

Weil-McLain code NO DISPLAY - BOILER RUNNING: homeowner questions

What does Weil-McLain code NO DISPLAY - BOILER RUNNING mean?

Display blank while boiler is operating. Display shows nothing but the boiler still runs. Communication from the control to the display is lost.

Is it safe to keep using my boiler with code NO DISPLAY - BOILER RUNNING?

Usually yes. Code NO DISPLAY - BOILER RUNNING is normally minor, but if it keeps coming back have it checked.

Can I reset Weil-McLain code NO DISPLAY - BOILER RUNNING myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code NO DISPLAY - BOILER RUNNING comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code NO DISPLAY - BOILER RUNNING near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Weil-McLain SVF Series 1 boiler manual, p. 103. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.