Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Error Code GAS VALVE FAULT: Gas valve output circuit fault (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code GAS VALVE FAULT on a boiler means: Gas valve output circuit fault. It is also called Weil-McLain diagnostic code GAS VALVE FAULT.

High severityBoilerUltra Series 4

Homeowner? What Weil-McLain code GAS VALVE FAULT means for you

Call a technician Your boiler is reporting: Gas valve output circuit fault. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code GAS VALVE FAULT mean?

U-Control detected a problem in the gas valve output circuit. Retries automatically; boiler resets if the condition clears. If not cleared, it retries in 1 hour and then needs a manual reset.

Applies to: Ultra Series 4 boilers

Common causes of Weil-McLain code GAS VALVE FAULT

  • Loose or damaged harness between gas valve and U-Control
  • Faulty U-Control
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
FAULT L1 POLARITYLine 1 polarity reversed
FAULT MANUAL LIMITManual limit fault
FLAME FAULTFlame detected when no flame should exist
FLAME LOSTFlame lost while running
FLUE TEMP TOO HIGHFlue gas temperature too high
GAS PRESSURE SW FAULTGas pressure switch open
GV FAULT EXPANSION BRDExpansion board gas valve output fault
HARDWARE FAULT 1Control board hardware fault 1
HARDWARE FAULT 2Control board hardware fault 2
HARDWARE FAULT 3Control board hardware fault 3
HARDWARE FAULT 4Control board hardware fault 4
HARDWARE FAULT 5Pilot valve output fault (board or harness short)

All Weil-McLain Boiler error codes →

Weil-McLain code GAS VALVE FAULT: homeowner questions

What does Weil-McLain code GAS VALVE FAULT mean?

Gas valve output circuit fault. U-Control detected a problem in the gas valve output circuit. Retries automatically; boiler resets if the condition clears. If not cleared, it retries in 1 hour and then needs a manual reset.

Is it safe to keep using my boiler with code GAS VALVE FAULT?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code GAS VALVE FAULT myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code GAS VALVE FAULT comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code GAS VALVE FAULT near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 boiler manual, p. 123. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977