Weil-McLain Error Code GV FAULT EXPANSION BRD: Expansion board gas valve output fault (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code GV FAULT EXPANSION BRD on a boiler means: Expansion board gas valve output fault. It is also called Weil-McLain diagnostic code GV FAULT EXPANSION BRD.

Medium severityBoilerUltra Series 4

Homeowner? What Weil-McLain code GV FAULT EXPANSION BRD means for you

Check, then call Your boiler is reporting: Expansion board gas valve output fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code GV FAULT EXPANSION BRD mean?

Gas valve output of the expansion board has a fault. Residential Ultra boilers do not use an expansion control board. Requires manual reset.

Applies to: Ultra Series 4 boilers

Common causes of Weil-McLain code GV FAULT EXPANSION BRD

  • Boiler size selected in the U-Control does not match the rating label
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
FAULT MANUAL LIMITManual limit fault
FLAME FAULTFlame detected when no flame should exist
FLAME LOSTFlame lost while running
FLUE TEMP TOO HIGHFlue gas temperature too high
GAS PRESSURE SW FAULTGas pressure switch open
GAS VALVE FAULTGas valve output circuit fault
HARDWARE FAULT 1Control board hardware fault 1
HARDWARE FAULT 2Control board hardware fault 2
HARDWARE FAULT 3Control board hardware fault 3
HARDWARE FAULT 4Control board hardware fault 4
HARDWARE FAULT 5Pilot valve output fault (board or harness short)
HARDWARE FAULT 6Control board hardware fault 6

All Weil-McLain Boiler error codes →

Weil-McLain code GV FAULT EXPANSION BRD: homeowner questions

What does Weil-McLain code GV FAULT EXPANSION BRD mean?

Expansion board gas valve output fault. Gas valve output of the expansion board has a fault. Residential Ultra boilers do not use an expansion control board. Requires manual reset.

Is it safe to keep using my boiler with code GV FAULT EXPANSION BRD?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Weil-McLain code GV FAULT EXPANSION BRD myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code GV FAULT EXPANSION BRD comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code GV FAULT EXPANSION BRD near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 boiler manual, p. 123. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.