Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Weil-McLain Error Code LOW WTR CUTOFF OPEN: Low water cutoff contacts open (Boiler)

Updated · by Aurora Star Tech Inc.

Weil-McLain error code LOW WTR CUTOFF OPEN on a boiler means: Low water cutoff contacts open. It is also called Weil-McLain diagnostic code LOW WTR CUTOFF OPEN.

High severityBoilerUltra Series 4

Homeowner? What Weil-McLain code LOW WTR CUTOFF OPEN means for you

Call a technician Your boiler is reporting: Low water cutoff contacts open. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the pressure gauge on the boiler. If it reads much lower than usual or near zero, or water is leaking, call a technician.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the boiler gas valve is open (handle in line with the pipe).
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Weil-McLain error code LOW WTR CUTOFF OPEN mean?

Low water cutoff contacts have been open for more than 1 second. Needs a manual reset of the U-Control, and sometimes a manual reset of the LWCO device depending on model.

Applies to: Ultra 80, 105, 155, 230, 299, 399

Common causes of Weil-McLain code LOW WTR CUTOFF OPEN

  • Real low water condition in the system
  • LWCO wiring open or disconnected
  • Faulty low water cutoff device
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Weil-McLain Boiler codes

CodeMeaning
HARDWARE FAULT 8Control board hardware fault 8
HIGH TEMP LIMITHigh temperature limit reached
HW FAULT EXPANSION BRDExpansion control board hardware fault
IGNITION FAULTNo flame after 5 ignition attempts
L1 POLARITYLine voltage polarity reversed
LIMIT OPENExternal limit open
LWCOLow water cutoff active / LWCO test
LWCO GREENLow water cutoff indicator green
LWCO REDLow water cutoff indicator red
MANUAL LIMITManual-reset limit circuit open (includes rollout switch)
NO DISPLAY - BOILER RUNNINGDisplay blank while boiler is operating
NO DISPLAY - NO 24VNo display, no 24V control power

All Weil-McLain Boiler error codes →

Weil-McLain code LOW WTR CUTOFF OPEN: homeowner questions

What does Weil-McLain code LOW WTR CUTOFF OPEN mean?

Low water cutoff contacts open. Low water cutoff contacts have been open for more than 1 second. Needs a manual reset of the U-Control, and sometimes a manual reset of the LWCO device depending on model.

Is it safe to keep using my boiler with code LOW WTR CUTOFF OPEN?

It depends on the cause. The boiler has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Weil-McLain code LOW WTR CUTOFF OPEN myself?

You can try one reset (power off for 30 seconds, then on). If Weil-McLain code LOW WTR CUTOFF OPEN comes back, the cause is still there and a licensed technician should check it.

Who can fix Weil-McLain code LOW WTR CUTOFF OPEN near me?

Aurora Star Tech Inc. repairs Weil-McLain boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Boiler Not Heating: What to Check

Troubleshooting guides

Source: Ultra Series 4 gas-fired water boiler manual, p. 120. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977