Viessmann Heat Pump Error Codes

Updated · by Aurora Star Tech Inc.

226 Viessmann Heat Pump error codes and diagnostic codes, with causes and troubleshooting steps for each. Select a code, or find your model below.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Viessmann Heat Pump error codes list

CodeMeaningSeverity
341 MCEMCE errorHigh
341 MCE errorMCE errorHigh
A2LA2L sensor faultHigh
Circuit Config. ErrorHeating circuit configuration errorLow
CommunicationIndoor to outdoor unit communication errorMedium
CONCondensate level too highMedium
Cooling temp.Cold buffer temperature sensor errorMedium
Curves Config. ErrorHeating curve configuration errorLow
DFDefrost display (normal)Low
DHW Tank Temp.DHW tank temperature sensor errorMedium
E(x)Indoor unit error code E(x)High
E10ReservedLow
E11ReservedLow
E12Heating return temperature sensor failureMedium
E13Heating outlet water temperature sensor failureMedium
E14High pressure protectionHigh
E15ReservedLow
E16Low pressure protectionHigh
E17ReservedLow
E18Water flow protectionMedium
E19Electric heating overload protectionHigh
E20Exhaust temperature overprotectionHigh
E23Fan 1 overload speed limitMedium
E24Fan 2 overload speed limitMedium
E25Inlet/outlet water temperature difference exceededMedium
E26Outlet water over heatHigh
E27Mixing outlet water temperature sensor failureMedium
E28Hot water return temp sensor failureMedium
E29Hot water outlet water temp sensor failureMedium
E34High pressure protection, 3 timesCritical
E36Low pressure protection, 3 timesCritical
E38Water flow protection, 3 timesCritical
E39Electric heating protection, 3 timesCritical
E40Discharge over heat protection, 3 timesCritical
E42Inlet/outlet water temp difference exceeded, 3 timesCritical
E43Outlet water temp too low, 3 timesCritical
E44Outlet water over temperature protection, 3 timesCritical
E50Inlet water temp failureMedium
E51Outlet water temp failureMedium
E52Coil temp failureMedium
E53Ambient temp failureMedium
E54Suction temp failureMedium
E55Anti-freeze temp failureMedium
E56Coil outlet water temp sensor failureMedium
E59EVI inlet temp failureMedium
E68Hot water temp failureMedium
E70IPM overheatHigh
E71Compressor start failureHigh
E72Compressor overcurrent (manual reset required)High
E73Input voltage phase lossHigh
E74IPM current sampling faultHigh
E75Overheat protection of drive board devicesHigh
E76Pre-charge failureMedium
E77DC bus over voltageHigh
E78DC bus under voltageHigh
E79AC input voltage under voltageMedium
E80IPM overheat stopHigh
E81 - E82ReservedLow
E8315 VDC under voltageMedium
E84 - E89ReservedLow
E90Compressor frequency not being maintainedLow
E91Compressor weak magnetic protection alarmMedium
E92Power unit overheating alarmLow
E93ReservedLow
E94AC input current down alarmMedium
E95EEPROM failure warningHigh
E96 - E99ReservedLow
E110Primary anti-freeze protectionLow
E111Secondary anti-freeze protectionLow
E112Anti-freeze protectionMedium
E114Room temp failureMedium
E312Anti-freeze protection, 3 timesCritical
E510EVI outlet temp failureMedium
E511Discharge temp failureMedium
E513System 1 pressure sensor failureMedium
E514Low ambient temp failureMedium
E515Outlet temp too low protectionMedium
E611Fan 1 failureHigh
E612Fan 2 failureHigh
E613Communication failure (main board with fan motor module board)High
E614ReservedLow
E615Communication failure (main board with fan motor 2 module board)Medium
E710AC input over current shutdownHigh
E711Input voltage sampling faultMedium
E712DSP and PFC communication failureHigh
E713Drive plate temperature faultMedium
E714DSP and communication board communication failureHigh
E715Main board communication failureMedium
E810 - E815ReservedLow
E910 - E912ReservedLow
EC(xx)Indoor unit error code EC(xx)High
EC 0dOutdoor unit malfunctionHigh
EC 07Outdoor fan speed outside normal rangeMedium
EC07Outdoor fan speed outside normal rangeMedium
EC5CHigh pressure sensor failureMedium
EC50Outdoor temperature sensor errorLow
EC 51Outdoor unit EEPROM parameter errorHigh
EC51Outdoor EEPROM parameter error or compressor driven chip EEPROM parameter errorHigh
EC 52Condenser coil temperature sensor T3 open or shortedMedium
EC52Open or short circuit of temperature sensor (outdoor)Medium
EC 53Outdoor room temperature sensor T4 open or shortedMedium
EC53Outdoor temperature sensor open or short circuit (T3, T4, TP, T2B, TH)Medium
EC 54Compressor discharge temperature sensor TP open or shortedMedium
EC54Open or short circuit of temperature sensor (outdoor)Medium
EC 55IGBT temperature sensor TH open or shortedMedium
EC55Open or short circuit of temperature sensor (outdoor)Medium
EC 56Evaporator coil outlet temperature sensor T2B open or shortedMedium
EC56Open or short circuit of temperature sensor (outdoor)Medium
EC57Refrigerant pipe temperature sensor errorLow
EC71Overcurrent failure of outdoor DC fan motorHigh
EC 72Missing phase failure of outdoor DC fan motorHigh
EC72Lack phase failure of outdoor DC fan motorHigh
EC73Zero-speed failure of outdoor DC fan motorHigh
EH(xx)Indoor unit error code EH(xx)High
EH 0bCommunication error between display board and main boardMedium
EH 0EWater-level alarm malfunctionMedium
EH0EWater-level alarm malfunctionLow
EH00EEPROM parameter errorHigh
EH00/EH0AIndoor unit EEPROM parameter errorHigh
EH02Zero crossing detection errorMedium
EH 03Indoor fan speed outside normal rangeMedium
EH03Indoor fan speed outside normal rangeMedium
EH06Indoor PCB and display board communication errorMedium
EH 3AExternal fan DC bus voltage too lowMedium
EH 3bExternal fan DC bus voltage too highMedium
EH 31Upper indoor fan speed outside normal rangeMedium
EH 32Lower indoor fan speed outside normal rangeMedium
EH 60Indoor room temperature sensor T1 open or shortedMedium
EH60Indoor temperature sensor open or short circuit (T1, T2)Medium
EH 61Evaporator coil temperature sensor T2 open or shortedMedium
EH61Open or short circuit of temperature sensor (indoor)Medium
EH62Open or short circuit of temperature sensor (indoor)Medium
EH 62Open or short circuit of temperature sensorMedium
EH65Open or short circuit of temperature sensor (indoor)Medium
EH 65Open or short circuit of temperature sensorMedium
EH b3Communication error between wired controller and indoor unitLow
EH bACommunication fault between external fan module and indoor unitMedium
EL(xx)Indoor unit error code EL(xx)High
EL 0CRefrigerant leakage detectedHigh
EL0CRefrigerant leakage detectionHigh
EL 01Indoor / outdoor unit communication errorMedium
EL01Indoor and outdoor unit communication errorHigh
EL 16Communication malfunction between adapter board and outdoor main boardHigh
EL16Communication fault between outdoor main board and transit boardMedium
F(x)Indoor unit error code F(x)High
FCFC display (normal)Low
FH 07Communication fault between indoor unit and auto-lifting panelMedium
FL 09Indoor and outdoor unit mismatchHigh
FrEFreeze protection activeHigh
GASA2L gas leakCritical
Heat Pump ModuleHeat pump error (outdoor unit)High
HICompressor high speedLow
HOPHigh over pressureHigh
HP Inlet Temp.Outdoor unit inlet temperature sensor errorMedium
HP Low PressureOutdoor unit low refrigerant pressureHigh
HP Outlet Temp.Outdoor unit outlet temperature sensor errorMedium
IDU PumpIndoor unit circulation pump errorMedium
Inlet Temp.Return temperature sensor errorMedium
LC 06IPM module high temperature protectionHigh
LC06High temperature protection of inverter module (IPM)Critical
LOCompressor low speedLow
Low BatteryLow batteryLow
Low PressureLow heating medium pressureHigh
LUPLow under pressureHigh
NSUNot set upMedium
Outlet Temp.Outlet temperature sensor errorMedium
Outside Temp.Outside temperature sensor errorMedium
P(x)Indoor unit error code P(x)High
P5Indoor units mode conflict (multi-outdoor match)Low
PC(xx)Indoor unit error code PC(xx)High
PC 0AHigh temperature protection of condenserHigh
PC0AHigh temperature protection of condenserMedium
PC 0FPFC module protectionHigh
PC0FPFC module protectionCritical
PC 0LLow ambient temperature protectionLow
PC0LLow temperature protection of outdoor unitMedium
PC 00IPM malfunction or IGBT over-strong current protectionCritical
PC00IPM malfunction or IGBT over-strong current protectionCritical
PC 01Over-voltage or low-voltage protectionHigh
PC01Overvoltage or low voltage protectionHigh
PC 02Compressor top temperature or IPM high temperature protectionCritical
PC02Compressor top temperature or IPM high temperature / high pressure protectionCritical
PC 03High or low pressure protectionHigh
PC03Low pressure protectionHigh
PC 04Inverter compressor drive errorHigh
PC04Inverter compressor drive errorHigh
PC 06Discharge temperature protection of compressorHigh
PC06Discharge temperature protection of compressorHigh
PC08Current overload protectionHigh
PC 08Current overload protectionHigh
PC 08/44/49Quick maintenance error codeMedium
PC 10Outdoor unit low AC voltage protectionHigh
PC10Outdoor unit low AC voltage protectionMedium
PC 10/11/12Quick maintenance error codeMedium
PC 11Outdoor unit main board DC bus high voltage protectionHigh
PC11Main control board DC bus high voltage protectionHigh
PC 12Outdoor unit main board DC bus high voltage protectionHigh
PC12Main control board DC bus high voltage protection / 341 MCE errorHigh
PC 30High pressure protectionHigh
PC30System high pressure protectionCritical
PC 31Low pressure protectionHigh
PC31System low pressure protectionHigh
PC 40Communication error between outdoor main PCB and IPM boardHigh
PC40Communication error between outdoor main chip and compressor driven chipMedium
PC 41Outdoor compressor current sampling circuit failureMedium
PC42Compressor start failureHigh
PC 43Outdoor compressor lack phase protectionHigh
PC43Outdoor compressor lack phase protectionHigh
PC 44Outdoor unit zero speed protectionHigh
PC44Outdoor unit zero speed protectionHigh
PC 45Outdoor unit IR chip drive failureHigh
PC45Outdoor unit IR chip drive failureHigh
PC 46Compressor speed out of controlHigh
PC46Compressor speed out of controlHigh
PC 49Compressor overcurrent failureHigh
PC49Compressor overcurrent failureCritical
PH(xx)Indoor unit error code PH(xx)High
PH90High temperature protection of evaporatorMedium
PH91Low temperature protection of evaporatorMedium
PL(xx)Indoor unit error code PL(xx)High
Power LEDPower indicator lightLow
Press. SensorSystem pressure sensor error (indoor unit)Medium
Room Temp.Room temperature sensor errorMedium
Temp. HC1Circuit 1 temperature sensor errorMedium
Temp. HC2Circuit 2 temperature sensor errorMedium
Thermal Cut-offFixed high limit tripped (indoor unit)High

Find codes by Viessmann model

Vitocal 100-S

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Vitocal 100-AW

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Vitocal 100-WA

AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056

Heat Pump troubleshooting guides

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977