Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: Check temperature sensors

Updated · by Aurora Star Tech Inc.

Check temperature sensors on a Viessmann heat pump: All sensors connect to the indoor unit and are NTC 10 kΩ. They connect to a low-voltage printed circuit board. Sensors: DHW tank temperature, system supply water temperature, room temperature (room sensors) and outdoor temperature.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Indoor unit sensors

How to fix check temperature sensors: step by step

  1. Measure sensor resistance and compare it with the temperature vs. resistance table in the manual.
  2. Replace the sensor if its resistance is out of range.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 86. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.