Viessmann Heat Pump: Preparing for service on flammable refrigerant systems
Preparing for service on flammable refrigerant systems on a Viessmann heat pump: Charging and handling precautions before work starts.
Applies to: Vitocal 100-WA, R-454B refrigerant
How to fix preparing for service on flammable refrigerant systems: step by step
- Make sure charging equipment is not contaminated by other refrigerants.
- Keep hoses and lines as short as possible to limit the refrigerant held in them.
- Keep cylinders in the correct position as per their instructions.
- Earth the refrigerating system before charging it with refrigerant.
- Label the system when charging is complete.
- Take great care not to overfill the refrigerating system.
- Do not install auxiliary devices that are potential ignition sources in the ductwork. Hot surfaces above 700°C (1292°F) and electrical switching devices are examples. Only devices declared suitable for R-454B may be installed in connected ductwork.
- Do not use means to speed up defrosting or cleaning other than those the manufacturer recommends.
- Store the appliance in a room without continuously operating ignition sources such as open flames, operating gas appliances or electric heaters.
- Do not pierce or burn the refrigerant circuit. Refrigerants may have no odour.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 56. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.