Viessmann Heat Pump: Repairs to sealed casings
Repairs to sealed casings on a Viessmann heat pump: Protect the enclosure and seals so the flammable atmosphere cannot enter.
Applies to: Sealed electrical and refrigerant enclosures
How to fix repairs to sealed casings: step by step
- Power off the device before removing a sealed cover.
- Do not modify the casing in ways that weaken its protection.
- Avoid cable damage, too many connectors on one terminal, and non-approved connectors.
- Check that seals are installed correctly and replace damaged hoses.
- Do not use silicone as a sealing agent; it can affect leak detectors.
- Use spare parts that meet the manufacturer's guidelines.
- Components rated for flammable atmospheres do not need to be powered off.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 90. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.