Viessmann Error Code EH65: Open or short circuit of temperature sensor (indoor) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EH65 on a heat pump means: Open or short circuit of temperature sensor (indoor). It is also called Viessmann diagnostic code EH65.

Medium severityHeat PumpVitocal IND-A

Homeowner? What Viessmann code EH65 means for you

Check, then call Your heat pump is reporting: Open or short circuit of temperature sensor (indoor). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EH65 mean?

The sampling voltage is below 0.06 V or above 4.94 V, so the sensor reading is out of range.

Applies to: Vitocal IND-A DLFUAA air handler, models 18XAK to 60XAK

Common causes of Viessmann code EH65

  • Open or shorted sensor
  • Poor sensor connection
  • Faulty indoor PCB
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
EH 60Indoor room temperature sensor T1 open or shorted
EH60Indoor temperature sensor open or short circuit (T1, T2)
EH 61Evaporator coil temperature sensor T2 open or shorted
EH61Open or short circuit of temperature sensor (indoor)
EH62Open or short circuit of temperature sensor (indoor)
EH 62Open or short circuit of temperature sensor
EH 65Open or short circuit of temperature sensor
EH b3Communication error between wired controller and indoor unit
EH bACommunication fault between external fan module and indoor unit
EL(xx)Indoor unit error code EL(xx)
EL 0CRefrigerant leakage detected
EL0CRefrigerant leakage detection

All Viessmann Heat Pump error codes →

Viessmann code EH65: homeowner questions

What does Viessmann code EH65 mean?

Open or short circuit of temperature sensor (indoor). The sampling voltage is below 0.06 V or above 4.94 V, so the sensor reading is out of range.

Is it safe to keep using my heat pump with code EH65?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code EH65 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EH65 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EH65 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal IND-A DLFUAA service manual, p. 23. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.