Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code E80: IPM overheat stop (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E80 on a heat pump means: IPM overheat stop. It is also called Viessmann diagnostic code E80.

High severityHeat PumpVitocal 100-AW AM2V

Homeowner? What Viessmann code E80 means for you

Call a technician Your heat pump is reporting: IPM overheat stop. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E80 mean?

The IPM on the fan driver board has stopped the unit for overheating. Usually the fan is not turning and draws high current, or the thermal grease is insufficient.

Applies to: Outdoor unit

Common causes of Viessmann code E80

  • Fan does not rotate and current is high
  • Too little thermally conductive silicone grease under the module
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
E74IPM current sampling fault
E75Overheat protection of drive board devices
E76Pre-charge failure
E77DC bus over voltage
E78DC bus under voltage
E79AC input voltage under voltage
E81 - E82Reserved
E8315 VDC under voltage
E84 - E89Reserved
E90Compressor frequency not being maintained
E91Compressor weak magnetic protection alarm
E92Power unit overheating alarm

All Viessmann Heat Pump error codes →

Viessmann code E80: homeowner questions

What does Viessmann code E80 mean?

IPM overheat stop. The IPM on the fan driver board has stopped the unit for overheating. Usually the fan is not turning and draws high current, or the thermal grease is insufficient.

Is it safe to keep using my heat pump with code E80?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code E80 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E80 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E80 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 83. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.