Viessmann Heat Pump: Connecting to the control board with PuTTY
Connecting to the control board with PuTTY on a Viessmann heat pump: A Windows computer or Android phone/tablet with PuTTY and a USB link is used to view and adjust the control board system run parameters, zone parameters and basic system program.
Applies to: Vitocal 100-WA control board
How to fix connecting to the control board with putty: step by step
- Install PuTTY on the computer or device.
- Open PuTTY and note the COM port the controller uses; check Device Manager under Ports (COM & LPT).
- If several COM ports are in use, unplug the controller to see which port disappears, then plug it back in.
- Connect the USB cable between the computer and the control board and make sure the controller is powered.
- Select Connection Type Serial, enter the COM number and set the speed (baud rate) to 250000.
- Click Default Settings under Saved Sessions and press Save so these settings load by default.
- Press Open on the Configuration page to start communicating with the controller.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
More commissioning tips for heat pump
Source: Vitocal 100-WA installation, service and operating manual, p. 82-83. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.