Viessmann Heat Pump: Indoor fan speed out of control
Indoor fan speed out of control on a Viessmann heat pump: The indoor fan is protected when its speed stays too low.
Applies to: DLCLRC indoor fan
Common causes of indoor fan speed out of control
- Indoor fan speed below 300 RPM
How to fix indoor fan speed out of control: step by step
- If the indoor fan speed stays below 300 RPM for 50 seconds, the fan shuts off and restarts 30 seconds later.
- If this protection engages 3 times during continuous restarts, the unit stops and the LED shows the failure.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: Vitocal 100-S DLCLRC service instructions, p. 10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.