Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EH60: Indoor temperature sensor open or short circuit (T1, T2) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EH60 on a heat pump means: Indoor temperature sensor open or short circuit (T1, T2). It is also called Viessmann diagnostic code EH60.

Medium severityHeat PumpDLFSHC

Homeowner? What Viessmann code EH60 means for you

Check, then call Your heat pump is reporting: Indoor temperature sensor open or short circuit (T1, T2). This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EH60 mean?

If the sampling voltage is below 0.06 V or above 4.94 V, the unit shows the failure code.

Applies to: DLFSHC indoor unit sensors T1 and T2

Common causes of Viessmann code EH60

  • Open or shorted sensor
  • Bad connection between sensor and PCB
  • Indoor main PCB fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
EH06Indoor PCB and display board communication error
EH 3AExternal fan DC bus voltage too low
EH 3bExternal fan DC bus voltage too high
EH 31Upper indoor fan speed outside normal range
EH 32Lower indoor fan speed outside normal range
EH 60Indoor room temperature sensor T1 open or shorted
EH 61Evaporator coil temperature sensor T2 open or shorted
EH61Open or short circuit of temperature sensor (indoor)
EH62Open or short circuit of temperature sensor (indoor)
EH 62Open or short circuit of temperature sensor
EH65Open or short circuit of temperature sensor (indoor)
EH 65Open or short circuit of temperature sensor

All Viessmann Heat Pump error codes →

Viessmann code EH60: homeowner questions

What does Viessmann code EH60 mean?

Indoor temperature sensor open or short circuit (T1, T2). If the sampling voltage is below 0.06 V or above 4.94 V, the unit shows the failure code.

Is it safe to keep using my heat pump with code EH60?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code EH60 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EH60 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EH60 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal IND-H DLFSHC service manual, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service