Viessmann Error Code E95: EEPROM failure warning (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E95 on a heat pump means: EEPROM failure warning. It is also called Viessmann diagnostic code E95.

High severityHeat PumpVitocal 100-AW AM2V

Homeowner? What Viessmann code E95 means for you

Call a technician Your heat pump is reporting: EEPROM failure warning. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E95 mean?

The EEPROM data is incorrect or the EEPROM is damaged.

Applies to: Outdoor unit

Common causes of Viessmann code E95

  • Burned data is incorrect
  • Read EEPROM data is incorrect
  • EEPROM damaged
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
E84 - E89Reserved
E90Compressor frequency not being maintained
E91Compressor weak magnetic protection alarm
E92Power unit overheating alarm
E93Reserved
E94AC input current down alarm
E96 - E99Reserved
E110Primary anti-freeze protection
E111Secondary anti-freeze protection
E112Anti-freeze protection
E114Room temp failure
E312Anti-freeze protection, 3 times

All Viessmann Heat Pump error codes →

Viessmann code E95: homeowner questions

What does Viessmann code E95 mean?

EEPROM failure warning. The EEPROM data is incorrect or the EEPROM is damaged.

Is it safe to keep using my heat pump with code E95?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code E95 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E95 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E95 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 84. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977