Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code PC00: IPM malfunction or IGBT over-strong current protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC00 on a heat pump means: IPM malfunction or IGBT over-strong current protection. It is also called Viessmann diagnostic code PC00.

Critical severityHeat PumpDLFSHC · Vitocal IND-H

Homeowner? What Viessmann code PC00 means for you

Stop and call Your heat pump is reporting: IPM malfunction or IGBT over-strong current protection. This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC00 mean?

The IPM sends an abnormal voltage signal to the compressor drive chip. The unit turns off and the code is displayed.

Applies to: Outdoor IPM module and compressor drive

Common causes of Viessmann code PC00

  • Faulty communication or compressor wires
  • Faulty IPM module board
  • Outdoor fan assembly fault

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
PC0AHigh temperature protection of condenser
PC 0FPFC module protection
PC0FPFC module protection
PC 0LLow ambient temperature protection
PC0LLow temperature protection of outdoor unit
PC 00IPM malfunction or IGBT over-strong current protection
PC 01Over-voltage or low-voltage protection
PC01Overvoltage or low voltage protection
PC 02Compressor top temperature or IPM high temperature protection
PC02Compressor top temperature or IPM high temperature / high pressure protection
PC 03High or low pressure protection
PC03Low pressure protection

All Viessmann Heat Pump error codes →

Viessmann code PC00: homeowner questions

What does Viessmann code PC00 mean?

IPM malfunction or IGBT over-strong current protection. The IPM sends an abnormal voltage signal to the compressor drive chip. The unit turns off and the code is displayed.

Is it safe to keep using my heat pump with code PC00?

No. Code PC00 is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.

Can I reset Viessmann code PC00 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Viessmann code PC00 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSHC Service Manual, p. 28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977