Viessmann Heat Pump: Thermostat mounting
Thermostat mounting on a Viessmann heat pump: Mount the thermostat on foam tape to seal the wire hole; silicone can also be used. This keeps drafts off the thermistor and helps prevent short cycling.
Applies to: Thermostat installation
How to fix thermostat mounting: step by step
- Seal the wire penetration behind the thermostat with foam tape or silicone.
- Keep the thermostat away from drafts.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA technical data manual, p. 12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.