Viessmann Error Code E710: AC input over current shutdown (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E710 on a heat pump means: AC input over current shutdown. It is also called Viessmann diagnostic code E710.

High severityHeat PumpVitocal 100-AW AM2V

Homeowner? What Viessmann code E710 means for you

Call a technician Your heat pump is reporting: AC input over current shutdown. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E710 mean?

AC input current is too high, from a faulty driver sampling circuit.

Applies to: Outdoor unit

Common causes of Viessmann code E710

  • Driver sampling circuit damaged
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
E515Outlet temp too low protection
E611Fan 1 failure
E612Fan 2 failure
E613Communication failure (main board with fan motor module board)
E614Reserved
E615Communication failure (main board with fan motor 2 module board)
E711Input voltage sampling fault
E712DSP and PFC communication failure
E713Drive plate temperature fault
E714DSP and communication board communication failure
E715Main board communication failure
E810 - E815Reserved

All Viessmann Heat Pump error codes →

Viessmann code E710: homeowner questions

What does Viessmann code E710 mean?

AC input over current shutdown. AC input current is too high, from a faulty driver sampling circuit.

Is it safe to keep using my heat pump with code E710?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code E710 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E710 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E710 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 82. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.