Viessmann Heat Pump: Checking and replacing fuses
Checking and replacing fuses on a Viessmann heat pump: Check the fuses in the junction box and on the control board.
Applies to: Vitocal 100-WA
Common causes of checking and replacing fuses
- Blown fuse, shown by an amber LED on the pump fuse
How to fix checking and replacing fuses: step by step
- Switch off the supply voltage.
- Open the connection space.
- Check the fuse and replace it if necessary.
- Use only fuses of the same type and characteristics.
- Install fuses without force and arrange them correctly.
- Disconnect the load circuit as well, since removing a fuse does not isolate the load.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 54. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.