Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code Curves Config. Error: Heating curve configuration error (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code Curves Config. Error on a heat pump means: Heating curve configuration error. It is also called Viessmann diagnostic code Curves Config. Error.

Low severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code Curves Config. Error means for you

Usually minor Your heat pump is reporting: Heating curve configuration error. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code Curves Config. Error mean?

Heating curve settings are inconsistent or invalid.

Applies to: Vitocal 100-AW AM2V controller

Common causes of Viessmann code Curves Config. Error

  • Heating curves configuration error
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code Curves Config. Error

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
341 MCE errorMCE error
A2LA2L sensor fault
Circuit Config. ErrorHeating circuit configuration error
CommunicationIndoor to outdoor unit communication error
CONCondensate level too high
Cooling temp.Cold buffer temperature sensor error
DFDefrost display (normal)
DHW Tank Temp.DHW tank temperature sensor error
E(x)Indoor unit error code E(x)
E10Reserved
E11Reserved
E12Heating return temperature sensor failure

All Viessmann Heat Pump error codes →

Viessmann code Curves Config. Error: homeowner questions

What does Viessmann code Curves Config. Error mean?

Heating curve configuration error. Heating curve settings are inconsistent or invalid.

Is it safe to keep using my heat pump with code Curves Config. Error?

Usually yes. Code Curves Config. Error is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code Curves Config. Error myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code Curves Config. Error comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code Curves Config. Error near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 69. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service