Viessmann Error Code E42: Inlet/outlet water temp difference exceeded, 3 times (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E42 on a heat pump means: Inlet/outlet water temp difference exceeded, 3 times. It is also called Viessmann diagnostic code E42.

Critical severityHeat PumpVitocal 100-AW

Homeowner? What Viessmann code E42 means for you

Stop and call Your heat pump is reporting: Inlet/outlet water temp difference exceeded, 3 times. This code is a safety shutdown. Turn the heat pump off and call a licensed technician. Do not keep resetting it. If you smell gas, leave the house and call your gas utility or 911 from outside.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E42 mean?

Inlet/outlet water temperature difference exceeded, occurred 3 times (repeat of E25). Requires manual reset of the outdoor unit.

Applies to: Vitocal 100-AW AM2V outdoor unit

Common causes of Viessmann code E42

  • Repeat of E25 temperature difference fault
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code E42

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Other Viessmann Heat Pump codes

CodeMeaning
E29Hot water outlet water temp sensor failure
E34High pressure protection, 3 times
E36Low pressure protection, 3 times
E38Water flow protection, 3 times
E39Electric heating protection, 3 times
E40Discharge over heat protection, 3 times
E43Outlet water temp too low, 3 times
E44Outlet water over temperature protection, 3 times
E50Inlet water temp failure
E51Outlet water temp failure
E52Coil temp failure
E53Ambient temp failure

All Viessmann Heat Pump error codes →

Viessmann code E42: homeowner questions

What does Viessmann code E42 mean?

Inlet/outlet water temp difference exceeded, 3 times. Inlet/outlet water temperature difference exceeded, occurred 3 times (repeat of E25). Requires manual reset of the outdoor unit.

Is it safe to keep using my heat pump with code E42?

No. Code E42 is a safety shutdown, so keep the heat pump off until a licensed technician has checked it.

Can I reset Viessmann code E42 myself?

Do not keep resetting it. Repeated resets can hide a safety problem; a licensed technician needs to find the cause.

Who can fix Viessmann code E42 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Viessmann Vitocal 100-AW AM2V installation, service and operating instructions, p. 76. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.