Viessmann Heat Pump: Optional electric strip heat accessory – overview and power supply
Optional electric strip heat accessory - overview and power supply on a Viessmann heat pump: A UL 1996 listed slip-in electric duct heater, installed by the licensed contractor in the supply duct downstream of the unit. It is ordered separately from Viessmann. The heat pump provides a 24 VAC AUX output that energizes the strip heater contactor. The heater high voltage comes from its own field supplied branch circuit and is not isolated by the heat pump disconnect.
Applies to: Vitocal 100-WA with optional electric strip heat accessory
How to fix optional electric strip heat accessory - overview and power supply: step by step
- Install the heater in the supply duct downstream of the unit.
- Run a separate branch circuit with a fused disconnect sized to the heater data plate.
- Do not take heater line voltage from the heat pump supply, junction box or terminal blocks.
- Use the 24 VAC AUX output from the heat pump to control the heater contactor.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA installation, service and operating instructions, p. 34. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.