Viessmann Error Code EC 07: Outdoor fan speed outside normal range (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EC 07 on a heat pump means: Outdoor fan speed outside normal range. It is also called Viessmann diagnostic code EC 07.

Medium severityHeat PumpVitocal IND-O

Homeowner? What Viessmann code EC 07 means for you

Check, then call Your heat pump is reporting: Outdoor fan speed outside normal range. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EC 07 mean?

Operation lamp flashes 12 times, timer lamp off. The outdoor fan speed is too low (below 100 RPM) or too high (above 1500 RPM) for 60 seconds. The unit stops and the failure clears 30 seconds later.

Applies to: DLFSOAH09XAK, DLFSOAH18XAK outdoor units

Common causes of Viessmann code EC 07

  • Outdoor fan speed below 100 RPM for 60 seconds
  • Outdoor fan speed above 1500 RPM for 60 seconds
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
E714DSP and communication board communication failure
E715Main board communication failure
E810 - E815Reserved
E910 - E912Reserved
EC(xx)Indoor unit error code EC(xx)
EC 0dOutdoor unit malfunction
EC07Outdoor fan speed outside normal range
EC5CHigh pressure sensor failure
EC50Outdoor temperature sensor error
EC 51Outdoor unit EEPROM parameter error
EC51Outdoor EEPROM parameter error or compressor driven chip EEPROM parameter error
EC 52Condenser coil temperature sensor T3 open or shorted

All Viessmann Heat Pump error codes →

Viessmann code EC 07: homeowner questions

What does Viessmann code EC 07 mean?

Outdoor fan speed outside normal range. Operation lamp flashes 12 times, timer lamp off. The outdoor fan speed is too low (below 100 RPM) or too high (above 1500 RPM) for 60 seconds. The unit stops and the failure clears 30 seconds later.

Is it safe to keep using my heat pump with code EC 07?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code EC 07 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EC 07 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EC 07 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSOAH service manual, PDF p. 8, 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.