Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: Read the Screen 1 live data columns

Updated · by Aurora Star Tech Inc.

Read the Screen 1 live data columns on a Viessmann heat pump: Screen 1 updates once per second. The column order is fixed, so read the sensor and output values in that order when checking the unit.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocal 100-WA

How to fix read the screen 1 live data columns: step by step

  1. Check column 2 for the operating state (H, H RL, H RM, H MP).
  2. Check SH and EEV for superheat and expansion valve position.
  3. Check HP and LP (psi) for high and low side pressure.
  4. Check CL, CH, FC, HW, AR, AS, LI and LO for compressor, freeze, tank, air and loop temperatures.
  5. Check column 17 (LFL) for gas percentage or a sensor error code.
  6. Check C, F and W for compressor, fan and water speed in percent of full speed.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Models

AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056

More service & test modes tips for heat pump

Source: Vitocal 100-WA installation, service and operating instructions, p. 46-47. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service