Applies to: R32 refrigeration circuit

How to fix leak detection for r32 systems: step by step

  1. Use an electronic leak detector suitable for R32 and free of potential ignition sources.
  2. Calibrate the detector in a refrigerant-free environment for the refrigerant used.
  3. Set the trip threshold to < 3 g/a, as printed in the manual.
  4. Use leak detection fluids only if they do not contain chlorine; chlorine-containing fluids can react with the refrigerant and cause rust.
  5. If a leak is found, put out any fire near the heat pump first.
  6. Do not solder leaks on the refrigeration circuit.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Models

0200280340430510780340043AM2V 020028AM2V 034043AM2V 051078

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 91. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.