Viessmann Heat Pump: Freeze switch activating in heating mode (well water only)
Freeze switch activating in heating mode (well water only) on a Viessmann heat pump: Freeze switch trips while the reversing valve switches during heating.
Applies to: Vitocal 100-WA well water systems
Common causes of freeze switch activating in heating mode (well water only)
- Too little water in heat cycle
- Freeze setting too high
- Bad freeze sensor
How to fix freeze switch activating in heating mode (well water only): step by step
- Follow the water flow procedure for the well system.
- Lower the freeze setting; contact technical service if needed.
- Replace the freeze sensor if faulty.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.