Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EH 0b: Communication error between display board and main board (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EH 0b on a heat pump means: Communication error between display board and main board. It is also called Viessmann diagnostic code EH 0b.

Medium severityHeat PumpVitocal IND-O

Homeowner? What Viessmann code EH 0b means for you

Check, then call Your heat pump is reporting: Communication error between display board and main board. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EH 0b mean?

Operation lamp flashes 9 times, timer lamp off.

Applies to: DLFSOAH09XAK, DLFSOAH18XAK indoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
EC57Refrigerant pipe temperature sensor error
EC71Overcurrent failure of outdoor DC fan motor
EC 72Missing phase failure of outdoor DC fan motor
EC72Lack phase failure of outdoor DC fan motor
EC73Zero-speed failure of outdoor DC fan motor
EH(xx)Indoor unit error code EH(xx)
EH 0EWater-level alarm malfunction
EH0EWater-level alarm malfunction
EH00EEPROM parameter error
EH00/EH0AIndoor unit EEPROM parameter error
EH02Zero crossing detection error
EH 03Indoor fan speed outside normal range

All Viessmann Heat Pump error codes →

Viessmann code EH 0b: homeowner questions

What does Viessmann code EH 0b mean?

Communication error between display board and main board. Operation lamp flashes 9 times, timer lamp off.

Is it safe to keep using my heat pump with code EH 0b?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code EH 0b myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EH 0b comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EH 0b near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSOAH service manual, PDF p. 15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service