Viessmann Error Code E713: Drive plate temperature fault (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code E713 on a heat pump means: Drive plate temperature fault. It is also called Viessmann diagnostic code E713.

Medium severityHeat PumpVitocal 100-AW AM2V

Homeowner? What Viessmann code E713 means for you

Check, then call Your heat pump is reporting: Drive plate temperature fault. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code E713 mean?

The drive plate temperature sensor reads open or short.

Applies to: Outdoor unit

Common causes of Viessmann code E713

  • Temperature sensor open or short circuit
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
E613Communication failure (main board with fan motor module board)
E614Reserved
E615Communication failure (main board with fan motor 2 module board)
E710AC input over current shutdown
E711Input voltage sampling fault
E712DSP and PFC communication failure
E714DSP and communication board communication failure
E715Main board communication failure
E810 - E815Reserved
E910 - E912Reserved
EC(xx)Indoor unit error code EC(xx)
EC 0dOutdoor unit malfunction

All Viessmann Heat Pump error codes →

Viessmann code E713: homeowner questions

What does Viessmann code E713 mean?

Drive plate temperature fault. The drive plate temperature sensor reads open or short.

Is it safe to keep using my heat pump with code E713?

It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.

Can I reset Viessmann code E713 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code E713 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code E713 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 83. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.