Viessmann Heat Pump: Freeze protection and power failure precautions
Freeze protection and power failure precautions on a Viessmann heat pump: Do not switch the unit off when outdoor air is below freezing, because leaving it powered protects the outdoor unit condenser. If power failure is a risk, isolate the heat pump heating circuit from the hydronic module with an additional exchanger and fill that circuit with antifreeze.
Applies to: Vitocal 100-AW AM2V outdoor unit
How to fix freeze protection and power failure precautions: step by step
- Keep the outdoor unit powered when outdoor air is below freezing.
- Where power failure is a risk, add an additional exchanger to isolate the heat pump circuit.
- Fill the heat pump heating circuit with antifreeze in that case.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
More commissioning tips for heat pump
Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 46. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.