Viessmann Error Code EC57: Refrigerant pipe temperature sensor error (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EC57 on a heat pump means: Refrigerant pipe temperature sensor error. It is also called Viessmann diagnostic code EC57.

Low severityHeat PumpVitocal 100-S · DLCURA

Homeowner? What Viessmann code EC57 means for you

Usually minor Your heat pump is reporting: Refrigerant pipe temperature sensor error. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EC57 mean?

The refrigerant pipe temperature sensor is reporting a fault.

Applies to: Outdoor unit sizes 18K to 60K

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code EC57

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
EC 54Compressor discharge temperature sensor TP open or shorted
EC54Open or short circuit of temperature sensor (outdoor)
EC 55IGBT temperature sensor TH open or shorted
EC55Open or short circuit of temperature sensor (outdoor)
EC 56Evaporator coil outlet temperature sensor T2B open or shorted
EC56Open or short circuit of temperature sensor (outdoor)
EC71Overcurrent failure of outdoor DC fan motor
EC 72Missing phase failure of outdoor DC fan motor
EC72Lack phase failure of outdoor DC fan motor
EC73Zero-speed failure of outdoor DC fan motor
EH(xx)Indoor unit error code EH(xx)
EH 0bCommunication error between display board and main board

All Viessmann Heat Pump error codes →

Viessmann code EC57: homeowner questions

What does Viessmann code EC57 mean?

Refrigerant pipe temperature sensor error. The refrigerant pipe temperature sensor is reporting a fault.

Is it safe to keep using my heat pump with code EC57?

Usually yes. Code EC57 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code EC57 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EC57 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EC57 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCURA installation instructions, p. 20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service