Viessmann Heat Pump: How to read the DLCURA cooling and heating performance tables
How to read the DLCURA cooling and heating performance tables on a Viessmann heat pump: Cooling tables are split by airflow (CFM). Each block lists outdoor dry bulb temperature down the side. Across the top are indoor wet bulb groups (60.8, 64.4, 66.2, 71.6 F) and, under each, indoor dry bulb values (73.4, 77.0, 80.6, 84.2 F). TC is total cooling capacity in BTU/hr, S/T is sensible-to-total ratio, and PI is total power input in kW. Heating tables list TC (total capacity, BTU/hr) and PI (total power, kW) against indoor dry bulb (60.8, 68.0, 71.6, 75.2 F) for each airflow block. Gray shaded cells are extrapolated data, not tested points.
Applies to: DLCURA 18K HH and 24K outdoor units (cooling and heating performance)
How to fix how to read the dlcura cooling and heating performance tables: step by step
- Pick the airflow block that matches the indoor blower CFM.
- Find the outdoor dry bulb row, then the indoor wet bulb and dry bulb column.
- Read TC for capacity, S/T for the sensible share, and PI for power draw.
- Treat gray shaded values as estimates only.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: DLCURA technical data manual, p. 16-24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.