Viessmann Heat Pump: Zero crossing detection error (no code)
Zero crossing detection error (no code) on a Viessmann heat pump: If the zero-crossing signal interval is not correct for 240 seconds, the unit stops and shows the failure code. The correct interval is 6 to 13 ms.
Applies to: DLFSOAH09XAK, DLFSOAH18XAK
Common causes of zero crossing detection error (no code)
- Zero-crossing signal interval outside 6 to 13 ms for 240 seconds
How to fix zero crossing detection error (no code): step by step
- Measure the zero-crossing signal interval; it should be 6 to 13 ms.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Source: DLFSOAH service manual, PDF p. 8. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.