Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code EL0C: Refrigerant leakage detection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code EL0C on a heat pump means: Refrigerant leakage detection. It is also called Viessmann diagnostic code EL0C.

High severityHeat PumpDLFSHC · Vitocal IND-H

Homeowner? What Viessmann code EL0C means for you

Call a technician Your heat pump is reporting: Refrigerant leakage detection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code EL0C mean?

In the first 5 minutes after compressor start, the evaporator coil temperature (T2) does not drop as expected while the compressor runs above 50 Hz. This happens three times and the unit shuts off.

Applies to: Indoor unit evaporator coil sensor T2 and refrigerant circuit

Common causes of Viessmann code EL0C

  • Refrigerant leak or undercharge
  • Blocked airflow or system blockage
  • Faulty T2 sensor

A technician checks these and 1 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Viessmann Heat Pump codes

CodeMeaning
EH65Open or short circuit of temperature sensor (indoor)
EH 65Open or short circuit of temperature sensor
EH b3Communication error between wired controller and indoor unit
EH bACommunication fault between external fan module and indoor unit
EL(xx)Indoor unit error code EL(xx)
EL 0CRefrigerant leakage detected
EL 01Indoor / outdoor unit communication error
EL01Indoor and outdoor unit communication error
EL 16Communication malfunction between adapter board and outdoor main board
EL16Communication fault between outdoor main board and transit board
F(x)Indoor unit error code F(x)
FCFC display (normal)

All Viessmann Heat Pump error codes →

Viessmann code EL0C: homeowner questions

What does Viessmann code EL0C mean?

Refrigerant leakage detection. In the first 5 minutes after compressor start, the evaporator coil temperature (T2) does not drop as expected while the compressor runs above 50 Hz. This happens three times and the unit shuts off.

Is it safe to keep using my heat pump with code EL0C?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code EL0C myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code EL0C comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code EL0C near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLFSHC Service Manual, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977