Viessmann Heat Pump: Operating pressure too low or low pressure limit tripping
Operating pressure too low or low pressure limit tripping on a Viessmann heat pump: Low operating pressure or low pressure limit trip.
Applies to: Vitocal 100-WA
Common causes of operating pressure too low or low pressure limit tripping
- Refrigerant leak
- Too little water flow in heat cycle
- Air restriction in cool cycle
- Bad low pressure limit
How to fix operating pressure too low or low pressure limit tripping: step by step
- Find and repair the refrigerant leak.
- Check loop pump, flow and water supply.
- Check the air filter and ductwork.
- Replace the low pressure limit if faulty.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.