Viessmann Error Code LC 06: IPM module high temperature protection (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code LC 06 on a heat pump means: IPM module high temperature protection. It is also called Viessmann diagnostic code LC 06.

High severityHeat PumpVitocal 100-S

Homeowner? What Viessmann code LC 06 means for you

Call a technician Your heat pump is reporting: IPM module high temperature protection. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code LC 06 mean?

The IPM module temperature is above the set limit.

Applies to: DLCURA outdoor units

Common causes of Viessmann code LC 06

  • Blocked indoor or outdoor airflow
  • Loose PCB or IPM heat sink screws
  • Refrigerant system fault

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code LC 06

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
HOPHigh over pressure
HP Inlet Temp.Outdoor unit inlet temperature sensor error
HP Low PressureOutdoor unit low refrigerant pressure
HP Outlet Temp.Outdoor unit outlet temperature sensor error
IDU PumpIndoor unit circulation pump error
Inlet Temp.Return temperature sensor error
LC06High temperature protection of inverter module (IPM)
LOCompressor low speed
Low BatteryLow battery
Low PressureLow heating medium pressure
LUPLow under pressure
NSUNot set up

All Viessmann Heat Pump error codes →

Viessmann code LC 06: homeowner questions

What does Viessmann code LC 06 mean?

IPM module high temperature protection. The IPM module temperature is above the set limit.

Is it safe to keep using my heat pump with code LC 06?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code LC 06 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code LC 06 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code LC 06 near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCURA Service Manual, p. 34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977