Viessmann Error Code PC 0A: High temperature protection of condenser (Heat Pump)

Updated · by Aurora Star Tech Inc.

Viessmann error code PC 0A on a heat pump means: High temperature protection of condenser. It is also called Viessmann diagnostic code PC 0A.

High severityHeat PumpVitocal 100-S

Homeowner? What Viessmann code PC 0A means for you

Call a technician Your heat pump is reporting: High temperature protection of condenser. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code PC 0A mean?

The outdoor pipe temperature is above 65 °C and the unit stops. It restarts only when the pipe temperature drops below 52 °C.

Applies to: DLCLRC outdoor units 36, 48, 58

Common causes of Viessmann code PC 0A

  • Faulty condenser temperature sensor or its connection
  • Outdoor ambient above 50 °C (54 °C for tropical models)
  • Blocked outdoor ventilation or dirty heat exchanger

A technician checks these and 2 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code PC 0A

Show all 22 models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Other Viessmann Heat Pump codes

CodeMeaning
NSUNot set up
Outlet Temp.Outlet temperature sensor error
Outside Temp.Outside temperature sensor error
P(x)Indoor unit error code P(x)
P5Indoor units mode conflict (multi-outdoor match)
PC(xx)Indoor unit error code PC(xx)
PC0AHigh temperature protection of condenser
PC 0FPFC module protection
PC0FPFC module protection
PC 0LLow ambient temperature protection
PC0LLow temperature protection of outdoor unit
PC 00IPM malfunction or IGBT over-strong current protection

All Viessmann Heat Pump error codes →

Viessmann code PC 0A: homeowner questions

What does Viessmann code PC 0A mean?

High temperature protection of condenser. The outdoor pipe temperature is above 65 °C and the unit stops. It restarts only when the pipe temperature drops below 52 °C.

Is it safe to keep using my heat pump with code PC 0A?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Viessmann code PC 0A myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code PC 0A comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code PC 0A near me?

Aurora Star Tech Inc. repairs Viessmann heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: DLCLRC Service Manual, p. 29. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977