Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: General troubleshooting approach and control board measurements

Updated · by Aurora Star Tech Inc.

General troubleshooting approach and control board measurements on a Viessmann heat pump: Start with the indoor unit display, since most codes show there. The outdoor board shows only a few errors. Use the flow charts for problems without a code. Use a digital multimeter and refer to the wiring diagrams for all board checks.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DLCLRC outdoor units, sizes 36 to 58, with indoor fan coil

How to fix general troubleshooting approach and control board measurements: step by step

  1. Use the diagnostic code tables and the flow charts to find the problem.
  2. Check the indoor unit display codes first. Check the outdoor board display if it shows a code.
  3. Tools needed: digital multimeter, Phillips and straight screwdrivers, needle-nose pliers, refrigeration gauges.
  4. Disconnect main power. Remove the outdoor unit top cover.
  5. Reconnect main power and probe the outdoor board inputs and outputs with the meter, using the wiring diagrams.
  6. Connect the red probe to the hot signal and the black probe to ground or negative.
  7. Note that some DC signals are pulsing. The pulse should move steadily whenever a signal is present.
  8. To check the indoor board, disconnect main power, remove the front cover and control box cover, and carefully remove the board.
  9. Place the indoor board face up on a plastic surface, not metal. Reconnect power and repeat the measurements.
  10. Disconnect main power before reinstalling any board to avoid shock and board damage.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Models

06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3

Source: DLCLRC Service Manual, p. 16. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977