Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Heat Pump: Water around base of unit

Updated · by Aurora Star Tech Inc.

Water around base of unit on a Viessmann heat pump: Water collecting at the base of the unit.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocal 100-WA

Common causes of water around base of unit

  • Water leak
  • Condensate from water coil or accumulator
  • Condensation pan not draining
  • Air coil freezing

How to fix water around base of unit: step by step

  1. Find and repair any water leak.
  2. Insulate the water coil and accumulator if they sweat.
  3. Check the pan for algae and blow out the condensate pipe restriction.
  4. Check for a dirty air filter or duct restriction if the air coil freezes.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

Models

AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056

Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 52. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service