Viessmann Heat Pump: Hydronic installation requirements

Updated · by Aurora Star Tech Inc.

Hydronic installation requirements on a Viessmann heat pump: The hydronic side must follow applicable standards and be sized for adequate flow. Flexible piping is needed to limit vibration. Heating medium piping must be insulated. A solids separator at the unit inlet is required for warranty.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitocal 100-AW AM2V hydronic system

How to fix hydronic installation requirements: step by step

  1. Size the piping between outdoor and indoor units for adequate flow (see technical data table).
  2. Connect the heat pump to the system with flexible piping.
  3. Insulate all heating medium pipes and connections.
  4. Install a solids separator at the unit inlet.
  5. Keep the minimum heating medium pressure at 8 PSI (0.5 bar).
  6. Pipe so the indoor unit can run the heating circuit without the outdoor unit.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Heat Pump codes

More commissioning tips for heat pump

Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.