Viessmann Heat Pump: Final tubing check before startup
Final tubing check before startup on a Viessmann heat pump: Verify factory tubing has not shifted in shipment. Feeder tubes are a common problem area.
Applies to: DLCURA indoor and outdoor units
Common causes of final tubing check before startup
- Tubing shifted during shipment
- Tubes rubbing against each other or sheet metal
How to fix final tubing check before startup: step by step
- Check factory tubing on both the indoor and outdoor units for shifting.
- Confirm no tubes rub against each other or any sheet metal.
- Pay close attention to the feeder tubes. Make sure their wire ties are secure and tight.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
06AAK09AAK12AAJ12AAK18AAK24AAK30AAKDLCLRCQ36AA3DLCLRCQ48AA3DLCLRCQ58AA3DLCURAQ18AA3DLCURAQ18AB3DLCURAQ24AA3DLCURAQ24AB3DLCURAQ30AA3DLCURAQ30AB3DLCURAQ36AA3DLCURAQ36AB3DLCURAQ48AA3DLCURAQ48AB3DLCURAQ60AA3DLCURAQ60AB3
Source: DLCURA Service Manual, p. 17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.