Viessmann Heat Pump: Duct design and install notes
Duct design and install notes on a Viessmann heat pump: Design ducts per ACCA Manual D or local code and keep them inside conditioned space. Attic duct should be low profile, laid on the joists and covered with 6-8 in. (150-200 mm) of insulation. Line the first 6 ft of supply and return with acoustic insulation and use flex duct for the first 6 ft from the grille. Do not undersize the return. Make turns smooth. Do not let screws or drilling reach the air coil.
Applies to: Ducted installs
How to fix duct design and install notes: step by step
- Design per ACCA Manual D or local code.
- Keep ducts inside conditioned space where possible.
- Insulate attic ducts with 6-8 in. (150-200 mm) of insulation.
- Line the first 6 ft of supply and return with acoustic insulation.
- Size the return to avoid pulsation and poor performance.
- Keep screws and drilling clear of the air coil.
If the unit shows an error code, look it up: Viessmann Heat Pump codes
Models
AP1T 027020AP1T 040029AP1T 052038AP1T 066049AP1T 077056
More commissioning tips for heat pump
Source: Vitocal 100-WA technical data manual, p. 13. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.